A practical reference on REV-ERB agonist: what it is, how it behaves, what the literature reports, and where the honest uncertainties sit.
This page was last updated on 2026-01-13 and is reviewed periodically as new material appears.
Identity and purity testing for SR9009 commonly uses liquid chromatography coupled with tandem mass spectrometry. This method separates the compound from matrix components and detects it by mass-to-charge transitions, providing sensitive and specific confirmation. Nuclear magnetic resonance spectroscopy can support structural identification, while high-performance liquid chromatography with ultraviolet detection may estimate purity. Because online products labeled as SR9009 may contain other substances or no active compound at all, independent verification is important in research settings. Certificates of analysis are useful but not a substitute for in-house testing.
Laboratory samples of SR9009 are typically supplied as a white to off-white powder. The compound dissolves readily in organic solvents such as dimethyl sulfoxide and ethanol, while its solubility in water is low. Because of this solubility profile, researchers often prepare concentrated stock solutions in an organic solvent before diluting them into aqueous assay buffers. Light exposure, moisture, and repeated freeze-thaw cycles can degrade many small molecules, so handling procedures usually aim to minimize these factors. Purity is commonly checked before use.
Quality control for research materials includes identity confirmation by nuclear magnetic resonance and purity assessment by high-performance liquid chromatography. Mass spectrometry provides molecular weight confirmation and can detect related impurities. Purchasers should request a certificate of analysis that lists lot-specific data. Online products advertised for human use often lack such documentation. Distinguishing legitimate research material from mislabeled or contaminated samples is a recurring challenge in independent testing, and independent laboratories may use orthogonal methods to verify identity.
Detection of SR9009 in biological samples usually relies on liquid chromatography coupled to tandem mass spectrometry. This approach separates the compound from matrix components and identifies it by mass transitions. Because SR9009 can undergo metabolism, laboratories often look for both parent drug and specific metabolites. Sample preparation may involve protein precipitation or solid-phase extraction. Method validation examines sensitivity, carryover, and interference from related substances, and reference standards are required for accurate calibration.
Storage recommendations for SR9009 reference material typically specify a freezer at -20 °C or lower, with protection from moisture and light. Repeated freeze-thaw cycles can degrade small molecules and introduce variability. Stock solutions in dimethyl sulfoxide are often aliquoted to avoid repeated handling. Stability studies may examine degradation under heat, humidity, and light exposure. The compound's thiophene and nitro groups can participate in reactions that alter analytical signals over time, so such changes affect quantitative results.
| Property | Value | Notes |
|---|---|---|
| Appearance | White to off-white powder | Typical for research-grade material |
| Solubility | Soluble in DMSO and ethanol; low aqueous solubility | Organic stock solutions are common |
| Typical storage temperature | -20 °C or lower | Protect from light and moisture |
| Common analytical method | LC-MS/MS | Used for detection and confirmation |
| Common synonyms | SR9009; Stenabolic | Stenabolic is an informal name |
Research interest in SR9009 grew from studies showing improved running endurance in mice after short treatment periods. Those experiments linked the compound to increased mitochondrial content and fatty acid oxidation in muscle, but the findings come from animal models and specific dosing schedules. Independent replication has been limited, and the pathways connecting REV-ERB activation to exercise performance are still being mapped. Whether similar responses occur in humans is an open question.
SR9009 is often grouped with compounds studied for circadian and metabolic regulation rather than with classical anabolic steroids. Its interactions with nuclear receptors differ from those of androgen receptor ligands, and its proposed mechanisms involve transcriptional control rather than direct hormone signaling. Some sources classify it as a metabolic modulator because of observed effects on energy utilization. The distinction matters for regulation and for interpreting research results across different compound classes.
SR9009 is a synthetic small molecule developed as a REV-ERB agonist. It binds to REV-ERBα and REV-ERBβ, nuclear receptors that help regulate circadian rhythms and metabolic gene expression. In cell and animal studies, the compound alters lipid and glucose handling and influences skeletal muscle oxidative capacity. Its exact effects in humans remain largely uncharacterized because controlled clinical trials have not been reported. The molecule is frequently described in preclinical literature as a metabolic modulator.
Most published work on SR9009 consists of preclinical studies. It is widely sold as a research chemical, a category that does not imply safety, efficacy, or pharmaceutical-grade quality. Sports anti-doping organizations have listed SR9009 as a prohibited substance, and its presence in an athlete sample can lead to sanctions. Legal status differs by country; in several jurisdictions it is not approved for human consumption and may be treated as an unapproved new drug.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. It is not a steroid, peptide, or natural hormone. In scientific literature, it appears under the code SR9009 and in non-scientific contexts as Stenabolic. The compound was identified through chemical screening efforts aimed at targeting circadian clock components. Its status remains investigational, and no regulatory agency has approved it as a human medicine.
Detection in biological samples can be complicated by rapid metabolism and low circulating concentrations. Some studies report phase I and phase II metabolites, and analytical methods may need to target those species in addition to the parent compound. Immunoassays are not broadly available, so mass spectrometry remains the main confirmatory approach. For anti-doping testing, laboratories look for SR9009 and its metabolites using validated LC-MS methods. Open questions include how long metabolites remain detectable and how different routes of administration alter detection windows.
In laboratory settings, SR9009 is typically characterized by liquid chromatography–mass spectrometry (LC-MS) or high-performance liquid chromatography with ultraviolet detection (HPLC-UV). These methods can confirm identity and estimate purity, but they require reference standards for accurate quantification. Because SR9009 is not a licensed pharmaceutical, no harmonized pharmacopeial monograph exists. Laboratories often validate in-house methods for matrices such as plasma, urine, or cell culture media. Sample preparation may involve protein precipitation or liquid-liquid extraction before analysis.
Many surgical procedures have been developed to create a neovagina, but none of them are ideal. Surgical intervention should only be considered after non-surgical pressure dilation methods have failed to produce a satisfactory result. A study in 2025 claims that vaginoplasty is not recommended in CAIS individuals. Neovaginoplasty can be performed using skin grafts, a segment of bowel, ileum, peritoneum, an absorbable adhesion barrier (Intercede, made by Johnson & Johnson), buccal mucosa, amnion, dura mater. or with the support of vaginal stents/expanders. Success of such methods should be determined by sexual function, and not just by vaginal length, as has been done in the past. Ileal or cecal segments may be problematic because of a shorter mesentery, which may produce tension on the neovagina, leading to stenosis. The sigmoid neovagina is thought to be self-lubricating, without the excess mucus production associated with segments of small bowel. Vaginoplasty may create scarring at the introitus (the vaginal opening), which requires additional surgery to correct. Vaginal dilators are required postoperatively to prevent vaginal stenosis from scarring. Inflatable vaginal stents are placed in the vagina deflated and then gently inflated. Other complications include bladder and bowel injuries. Yearly exams are required as neovaginoplasty carries a risk of carcinoma, although carcinoma of the neovagina is uncommon. Neither neovaginoplasty nor vaginal dilation should be performed before puberty.
=== Manufacturing === HPLC has many applications in both laboratory and clinical science. It is a common technique used in pharmaceutical development, as it is a dependable way to obtain and ensure product purity. While HPLC can produce extremely high quality (pure) products, it is not always the primary method used in the production of bulk drug materials. According to the European pharmacopoeia, HPLC is used in only 15.5% of syntheses. However, it plays a role in 44% of syntheses in the United States pharmacopoeia. This could possibly be due to differences in monetary and time constraints, as HPLC on a large scale can be an expensive technique. An increase in specificity, precision, and accuracy that occurs with HPLC unfortunately corresponds to an increase in cost.
==== Non-genomic mechanisms ==== Testosterone signals not only through the nuclear AR, but also through mARs, including ZIP9 and GPRC6A. It has been proposed that differential signaling through mARs may be involved in the dissociation of the anabolic and androgenic effects of AAS. Indeed, DHT has less than 1% of the affinity of testosterone for ZIP9, and the synthetic AAS metribolone and mibolerone are ineffective competitors for the receptor similarly. This indicates that AAS do show differential interactions with the AR and mARs. However, women with complete androgen insensitivity syndrome (CAIS), who have a 46,XY ("male") genotype and testes but a defect in the AR such that it is non-functional, are a challenge to this notion. They are completely insensitive to the AR-mediated effects of androgens like testosterone, and show a perfectly female phenotype despite having testosterone levels in the high end of the normal male range. These women have little or no sebum production, incidence of acne, or body hair growth (including in the pubic and axillary areas). Moreover, CAIS women have lean body mass that is normal for females but is of course greatly reduced relative to males. These observations suggest that the AR is mainly or exclusively responsible for masculinization and myotrophy caused by androgens. The mARs have however been found to be involved in some of the health-related effects of testosterone, like modulation of prostate cancer risk and progression.
Isotopic reference materials are compounds (solids, liquids, gasses) with well-defined isotopic compositions and are the ultimate sources of accuracy in mass spectrometric measurements of isotope ratios. Isotopic references are used because mass spectrometers are highly fractionating. As a result, the isotopic ratio that the instrument measures can be very different from that in the sample's measurement. Moreover, the degree of instrument fractionation changes during measurement, often on a timescale shorter than the measurement's duration, and can depend on the characteristics of the sample itself. By measuring a material of known isotopic composition, fractionation within the mass spectrometer can be removed during post-measurement data processing. Without isotope references, measurements by mass spectrometry would be much less accurate and could not be used in comparisons across different analytical facilities. Due to their critical role in measuring isotope ratios, and in part, due to historical legacy, isotopic reference materials define the scales on which isotope ratios are reported in the peer-reviewed scientific literature. Isotope reference materials are generated, maintained, and sold by the International Atomic Energy Agency (IAEA), the National Institute of Standards and Technology (NIST), the United States Geologic Survey (USGS), the Institute for Reference Materials and Measurements (IRMM), and a variety of universities and scientific supply companies.
=== Mechanism of action === Levobunolol is a non-cardioselective beta blocker, that is, it blocks beta-1 receptors as well as beta-2 receptors. The latter type dominates in the ciliary body, where it controls aqueous humour production. Blocking this type of receptor reduces aqueous humour production, lowering intraocular pressure. The substance has no relevant membrane stabilizing effect or intrinsic sympathomimetic activity. Like other beta blockers, and unlike the anti-glaucoma medication pilocarpine, levobunolol has no effect on accommodation and pupil size.
Sources: en.wikipedia.org
=== October === 1 October – Prime Minister Rishi Sunak announces £20m of levelling up funding to help regenerate seven Scottish towns that are described as having been overlooked. 2 October – ScotRail begins a six months trial during which peak time train fares are scrapped. 3 October – Aberdeen City Council says that reinforced autoclaved aerated concrete (RAAC) is likely to have been used in hundreds of properties in the city. 4 October – Police Scotland pays £60,000 compensation to four traffic officers told to shave off their beards before the force implemented its delayed proposals for a clean shaven policy. 5 October – Labour's Michael Shanks wins the Rutherglen and Hamilton West by-election. 6 October – Police Scotland scraps plans to recruit an extra 200 officers in January 2024 as it attempts to save costs following a projected overspend of £19m. 7 October – The Met Office issues an amber weather alert for heavy rain in Scotland, while roads and train services are disrupted by flooding. Ten people are airlifted to safety after heavy rain causes landslides on two roads in Argyll. 9 October – Bernard Cowan, a grandfather who grew up in the Glasgow area, is confirmed as one of the people killed during a series of attacks launched by Hamas against Israel on 7 October. Humza Yousaf, the First Minister of Scotland, condemns the attacks and expresses concern for his in-laws, who are "trapped" in Gaza after travelling there to visit relatives. The Scottish Medicines Consortium (SMC) approves the weight loss drug semaglutide for use by NHS Scotland.
== Theory == The use of micelles in high performance liquid chromatography was first introduced by Armstrong and Henry in 1980. The technique is used mainly to enhance retention and selectivity of various solutes that would otherwise be inseparable or poorly resolved. Micellar liquid chromatography (MLC) has been used in a variety of applications including separation of mixtures of charged and neutral solutes, direct injection of serum and other physiological fluids, analysis of pharmaceutical compounds, separation of enantiomers, analysis of inorganic organometallics, and a host of others. One of the main drawbacks of the technique is the reduced efficiency that is caused by the micelles. Despite the sometimes poor efficiency, MLC is a better choice than ion-exchange LC or ion-pairing LC for separation of charged molecules and mixtures of charged and neutral species. Some of the aspects which will be discussed are the theoretical aspects of MLC, the use of models in predicting retentive characteristics of MLC, the effect of micelles on efficiency and selectivity, and general applications of MLC. Reverse phase high-performance liquid chromatography (RP-HPLC) involves a non-polar stationary phase, often a hydrocarbon chain, and a polar mobile or liquid phase. The mobile phase generally consists of an aqueous portion with an organic addition, such as methanol or acetonitrile. When a solution of analytes is injected into the system, the components begin to partition out of the mobile phase and interact with the stationary phase.
Choosing a software tool for structural alignment can be a challenge due to the large variety of available packages that differ significantly in methodology and reliability. A partial solution to this problem was presented in and made publicly accessible through the ProCKSI webserver. A more complete list of currently available and freely distributed structural alignment software can be found in structural alignment software. Properties of some structural alignment servers and software packages are summarized and tested with examples at Structural Alignment Tools in Proteopedia.Org.
Compounds and their metabolites need to be removed from the body via excretion, usually through the kidneys (urine) or in the feces. Unless excretion is complete, accumulation of foreign substances can adversely affect normal metabolism. There are three main sites where drug excretion occurs. The kidney is the most important site and it is where products are excreted through urine. Biliary excretion or fecal excretion is the process that initiates in the liver and passes through to the gut until the products are finally excreted along with waste products or feces. The last main method of excretion is through the lungs (e.g. anesthetic gases). Excretion of drugs by the kidney involves 3 main mechanisms:
Sources: en.wikipedia.org
Research-grade SR9009 is typically stored frozen at about minus twenty degrees Celsius, protected from light and moisture. Stock solutions are often kept in aliquots to avoid repeated freeze-thaw cycles. Specific storage conditions should follow the supplier's documentation.
Liquid chromatography with tandem mass spectrometry is widely used to detect and confirm SR9009 in laboratory samples. The technique offers high sensitivity and can distinguish the target compound from related substances. Nuclear magnetic resonance and ultraviolet detection may support identity and purity checks.
Online products labeled as SR9009 may vary in identity, purity, and actual content. Independent testing helps confirm that a sample matches its label and does not contain unexpected contaminants. This is important for reproducible research and for interpreting experimental results.
Liquid chromatography-tandem mass spectrometry is a common approach. It can detect the parent compound and its metabolites in biological matrices.